Key Takeaways:
Hydrostatic films damp vibration well, so unexpected vibration usually points to oil supply or process issues. A simple monitoring routine catches problems before they reach the workpiece.
Good Damping, Bad Signal
One of hydrostatic support's strengths is excellent oil-film vibration damping. That means when unusual vibration does appear, it is a meaningful signal—not normal behavior—and deserves prompt attention.

What to Monitor
Track cavity pressure, oil flow, and film thickness trend over time. Abrupt or drifting changes usually precede accuracy loss. Combined with periodic checks of oil cleanliness (NAS 5) and temperature (35±5°C), this gives early warning.
Interpreting the Data
Vibration that rises with load often indicates supply pressure sag or a restricted cavity. Vibration independent of load may point to the process or foundation. Because the film itself is stable by design, most vibration issues trace back to the oil supply or external excitation—both fixable without opening the bearing.